Wouxun KG-UV9G
Wouxun KG-UV9G
Two way Radio (GMRS radio)
Wouxun KG-UV9G. This report has been prepared on behalf of Quanzhou Wouxun Electronics Co., Ltd. and their product Two way Radio( GMRS radio), Model: KG-UV9G, FCC ID: WVTWOUXUN19 or the EUT (Equipment under Test) as referred to in the rest of this report.
Note: The series product models KG-UV9G (Plus), KG-UV9GX, KG-UV9GW are electrically identical with model KG-UV9G, we selected KG-UV9G for fully testing, the differences details was explained in the declaration letter.
Wouxun KG-UV9G Technical Specification
Device Type: | Portable |
Exposure Category: | General Population/Uncontrolled Exposure |
Antenna Type(s): | External Antenna |
Body-Worn Accessories: | Belt Clip |
Face-Head Accessories: | None |
Modulation Type: | PTT_FM |
Frequency Band: | 462MHz(462.5500-462.7250MHz); 462MHz(462.5625-462.7125MHz); 467MHz(467.5500-467.7250 MHz); 467MHz(467.5675-467.7125 MHz) |
ERP Power: | 462MHz(462.5500-462.7250MHz): 37.42 dBm 462MHz(462.5625-462.7125MHz) : 36.49 dBm 467MHz(467.5500-467.7250 MHz): 37.33 dBm 467MHz(467.5675-467.7125 MHz) : 26.86 dBm |
Power Source: | 7.4 VDC From Rechargeable Battery |
Normal Operation: | Face Up and Body-worn |
SAR Limits
FCC Limit
SAR (W/kg) | ||
EXPOSURE LIMITS | (General Population / Uncontrolled Exposure Environment) |
(Occupational / Controlled Exposure Environment) |
Spatial Average (averaged over the whole body) |
0.08 | 0.4 |
Spatial Peak (averaged over any 1 g of tissue) |
1.60 | 8.0 |
Spatial Peak (hands/wrists/feet/ankles averaged over 10 g) |
4.0 | 20.0 |
CE Limit
EXPOSURE LIMITS | SAR (W/kg) | |
(General Population / Uncontrolled Exposure Environment) |
(Occupational / Controlled Exposure Environment) |
|
Spatial Average (averaged over the whole body) |
0.08 | 0.4 |
Spatial Peak (averaged over any 10 g of |
2.0 | 10 |
Spatial Peak (hands/wrists/feet/ankles averaged over 10 g) |
4.0 | 20.0 |
Population/Uncontrolled Environments are defined as locations where there is the exposure of
individual who have no knowledge or control of their exposure.
Occupational/Controlled Environments are defined as locations where there is exposure that may
be incurred by people who are aware of the potential for exposure (i.e. as a result of employment
or occupation).
General Population/ Uncontrolled environments Spatial Peak limit 1.6 W/kg (FCC) & 2.0 W/kg (CE)
applied to the EUT.