Anytone AT-588UV Plus

| junio 9, 2021

FCC Test Report

Anytone AT-588UV Plus

  • FCC ID: T4K-588UVBPLUS
  • PRODUCT DESIGNATION : Dual Band Mobile Radio
    BRAND NAME: AnyTone
  • MODEL NAME: 588UVB PLUS, 588UVE PLUS, DB-750X, 5888UV, 588UVPLUS
  • APPLICANT: Qixiang Electron Science & Technology Co., Ltd.
  • DATE OF ISSUE :  May 13, 2021
  • STANDARD(S)  : FCC Part 15 Rules

Anytone AT-588UV Plus

VERIFICATION OF COMPLIANCE

Applicant: Qixiang Electron Science & Technology Co., Ltd.
Product Designation Dual Band Mobile Radio
Brand Name AnyTone
Test Model AT-588UVB Plus
Series Model(s)
  • AT-588UVE Plus
  • DB-750X
  • AT-5888UV
  • AT- 588UV Plus
Difference Description All the same except the model name.
Measurement Procedure: ANSI C63.4: 2014
Deviation: No any deviation from the test method.
Date of Test: Mar. 22, 2021~May 13, 2021
Condition of Test Sample: Normal
Test Result: Pass

The above equipment was tested by Attestation Of Global Compliance (Shenzhen) Co., Ltd. for compliance with
the requirements set forth in the FCC Rules and Regulations Part 15, the measurement procedure according to
ANSI C63.4:2014.

This said equipment in the configuration described in this report shows the maximum emission levels emanating from equipment are within the compliance requirements. The test results of this report relate only to the tested sample identified in this report.

PRODUCT INFORMATION

The EUT is a Dual Band Mobile Radio designed for voice communication. It is designed by way of utilizing the F3E modulation achieves the system operating.

A major technical description of EUT is described as following:

Communication Type Voice / Tone only
Modulation FM
RX Frequency Range 136-174 MHz, 220-225MHz, 400-512MHz (Scanning Receiver)
Emission Type F3E
Antenna Designation Detachable
Antenna Gain 0dBi
Hardware Version QX588UV-MBP
Software Version V1.0
Power Supply DC 13.8V

 

MEASUREMENT UNCERTAINTY

The uncertainty is calculated using the methods suggested in the “Guide to the Expression of Uncertainty in measurement” (GUM) published by CISPR and ANSI.

  • Uncertainty of Conducted Emission, Uc = ±3.1 dB
  • Uncertainty of Radiated Emission below 1GHz, Uc = ±4.0 dB
  • Uncertainty of Radiated Emission above 1GHz, Uc = ±4.8 Db

SUMMARY OF TEST RESULTS


FCC RULES DESCRIPTION OF TEST RESULT
§15.107 Conduction Emission Not applicable
§15.109 Radiated Emission Compliant
§15.111 Antenna Conducted Power for receivers Compliant
§ 15.121(b) Scanning receivers and frequency converters used with scanning receivers Compliant

NOTE: The device under test is a DC power supply device, and the conducted disturbance test is not
applicable.

Anytone AT-588UV Plus Inside View

Qixiang Electron Science & Technology Co., Ltd.

May 27, 2021

Office of Engineering Technology
Federal Communications Commission
7435 Oakland Mills Road
Columbia, MD 21046
USA

Subject: Explanation of differences between product types

FCC ID : T4K-588UVBPLUS

Model Number: 588UVB PLUS, 588UVE PLUS, DB-750X, 5888UV, 588UVPLUS

To Whom It May Concern:

We, The Qixiang Electron Science & Technology Co., Ltd. hereby declare that the
model : 588UVE PLUS, DB-750X, 5888UV, 588UVPLUS is identical with the model :
588UVB PLUS, except the model name.

Except for the different above, no other modification is performed.
Sincerely,

Signature:

About the Author: